Skip to content
VoltAire AT19RNSXX
VoltAire AT19RNSXX (back)

AT Telecom Series

AT19RNSXX

19,000 BTU/hr (5,567W) Enclosure Air Conditioner

230VAC 50/60Hz • Stainless Steel (NEMA 4X) • No Heat

Made in USA UL/cUL Listed NEMA 4X BABA Compliant

19,000

BTU/hr

230V

Voltage

R-134A

Refrigerant

$7,976

Built to Order • 4-6 weeks

Request a Quote →
Need a different base unit? Heat, stainless steel, or different voltage. Add ethernet, filter, and adapter options below.

Technical Specifications

Capacity 19,000 BTU/hr (5,567W)
Voltage 230VAC 50/60Hz
Height 53.03"
Width 21.62"
Depth 17.00"
Weight 200.0 lbs (90.7 kg)
Refrigerant R-134A
NEMA Rating Type 4X
Operating Range -40°F to 131°F
MCA (Amps) 24.4A
Compressor Rotary
Cabinet Finish Stainless
Electric Heat No Heat
Controller DIP switch board (Ethernet opt.)
Cabinet Material Acrylume sheet steel
Certifications UL/cUL (UL 484), NEMA 4

Technical Drawings — from the AT Telecom Series installation manual (dimensions in inches)

Unit Dimensions

AT19RNSXX dimensions drawing

Cabinet Cutout

AT19RNSXX cutout dimensions drawing

Unit Configuration

AT19RNSXX configuration drawing

Nominal Cooling Capacity

AT19RNSXX nominal cooling capacity chart

Sensible BTU/hr at 95°F, 113°F, and 131°F ambient temperatures

This Unit Replaces

The AT19RNSXX is engineered as a replacement for these McLean, Hoffman, Pentair, and nVent models. Same capacity, same voltage — designed to get you back up and running fast.

Serviceability

Built for Technicians

Understanding the cost to deploy a truck, every VoltAire unit features a centralized electrical compartment accessed with a single 5/16” driver — a tool that’s already on your truck. When you remove the cosmetic cover, it reveals the Acrylume cabinet. Six screws on top and all your electronics are visibly laid out in the service tray. A bottom panel gives you access to the compressor and motors.

Unlike competitors where you might have to remove several components to access something buried inside, VoltAire units are designed so most repairs can occur without even taking the unit off the cabinet. We also use commonly available parts you’re likely already carrying, so you don’t have to overnight a special relay from the factory.

Compressor
Control Boards
Contactors & Relays
Fans & Motors

Watch: Easy to Service

Built for technicians by technicians — see how fast routine service goes.

Service Access Design

1

Remove Cosmetic Cover

Common Torx fastener reveals the Acrylume cabinet underneath.

2

Open Electrical Tray

Six screws on top. Compressor, board, contactors, fans all laid out visibly.

3

Access Compressor

Remove bottom panel for direct access to compressor and motor compartment.

Built to Last

Premium Materials. Uncompromising Durability.

Every component is selected for longevity in harsh outdoor environments. No shortcuts. No substitutions.

Acrylume Cabinet

Coated with a clear organic resin for superior corrosion resistance. Outperforms standard galvanized steel in salt fog environments.

ElectroFin E-Coated Condenser Coil

Dipped Modine Luvata E-Coat extends coil life in the harshest salt fog environments. Over 6,000 hours of salt spray testing.

Stainless Steel Hardware

All exterior fasteners, the drain pan, and evaporator pan are stainless steel. Every metal surface that contacts water is corrosion-proof.

Rosenberg EC Fans

Engineered in Germany, manufactured in France. High IP rating protects against dust and water ingress for extended service life.

Danfoss TXV

The only TXV manufacturer using stainless steel exterior with copper interior. We source exclusively from Danfoss for reliability.

Marine-Grade Aluminum Cover

Powder-coated 5052 marine-grade aluminum alloy cosmetic cover. Built for outdoor exposure in coastal and industrial environments.

Quality Assurance

5-Point Factory Testing

It takes longer to build units right. Every VoltAire unit undergoes an extensive testing and retesting process on the assembly line in Orlando, FL. Each unit has a “Traveler” — accompanying paperwork verified at every station with fresh eyes.

1

Nitrogen Burst

Pressurized to 425 PSI to verify all brazes and connections are solid.

2

Helium Leak Test

The gold standard. Helium is the smallest particle — smaller than R-134A molecules — finding microscopic leaks invisible to other methods.

3

Vacuum Decay

Circuit pulled to 20 microns. Solenoid tripped. Plateau monitored — must stay below 500 microns to pass.

4

Second Vacuum Decay

A second independent vacuum decay test on a separate system. When passed, the unit is charged with refrigerant.

5

Refrigerant Leak

Fully charged, the unit undergoes a final sniffer test ensuring zero refrigerant leaks in the system.

Why helium leak testing matters: Helium atoms are smaller than any refrigerant molecule, making helium the only gas capable of detecting microscopic leaks that would go unnoticed with standard pressure testing. It’s the same method used in aerospace and medical device manufacturing — and it’s standard on every VoltAire unit.

Watch: Quality, Start to Finish

What goes into a cabinet cooler that lasts — materials, assembly, and testing.

Standard Equipment

Digital Temperature Control Board

Every VoltAire unit ships with a 10-position DIP switch control board — no mechanical thermostats. Adjustable cooling setpoints from 72–93°F, configurable hysteresis, deadband, and alarm differential. Built-in anti-short-cycling protection prevents compressor damage.

If the board ever fails in the field, you can wire up a standard mechanical thermostat as a temporary bypass while a replacement ships — keeping your enclosure protected without waiting for parts.

Adjustable setpoint: 72-93°F (default 81°F)
Fail-safe alarm relay with dry contacts
3-strike soft lockout protection
Remote temp sensor with 6-foot lead wire
LED status display & one-button test mode

Watch: Temperature Control Board Functions

VoltAire manufacturing walks through the digital control board — setpoints, alarms, and how each function works.

Optional Upgrade

Ethernet Controller

For critical applications requiring remote monitoring, the VoltAire Ethernet Controller replaces the standard DIP switch board with full network connectivity. One truck roll for a thermal alarm costs more than the controller.

Modbus TCP/IP + Lead-Lag +$736
Add SNMP Protocol +$884
Add BACnet Protocol +$979

Lead-Lag redundancy connects two units for automatic failover. Web-based management from any browser. Remote temperature monitoring and alarm notifications. SNMP and BACnet licenses are preloaded at the factory — drop-in integration with your existing monitoring or building automation systems, no field commissioning.

Add Ethernet to Your Configuration →

Configure Your AT19

Choose voltage, cabinet finish, heat, controller, filter, and adapter options and see your live model number and pricing.

Open the Configurator →

Need a Different Voltage, Finish, or Heater?

Those options change the base SKU. Pick another AT19 variant below, or use the full AT19 configurator.