10-Year TCO Calculator

Total Cost of Ownership Calculator

Compare the real cost of enclosure cooling options over 10 years — capital, electricity, maintenance, and downtime risk. Heat exchangers vs air conditioners vs the cost of doing nothing.

1. Pick 2–4 Options to Compare

VoltAire Heat Exchanger

VoltAire Air Conditioner

Competitor Equivalent

Status Quo

Selected: of 4 max

2. Your Operating Conditions

U.S. industrial average: $0.08–0.15

24/7 = 8,760. Single shift = 2,080.

Industrial typical: $1,000–$10,000/hr

From notification to repair completion

Cumulative Cost Over Years

Cost Breakdown ( Years)

Option Capital Electricity Maintenance Downtime Risk Total

Estimates based on published list pricing and industry-typical operating data. Actual costs vary by site, utility rates, and equipment selection. Use this calculator as a planning tool, not a binding quote. *Heat exchanger capital costs are illustrative estimates — these units are quote-only, so request a quote for current pricing.

Methodology

How TCO Is Calculated

Total Cost of Ownership is the sum of four cost components over your selected time horizon.

Capital Cost

Purchase price + installation labor. Replacement costs added when equipment reaches end-of-service-life within the time horizon.

Electricity Cost

Average running watts × annual operating hours × your electricity rate. Heat exchangers consume far less than air conditioners (fans only, no compressor).

Maintenance Cost

Typical annual service expenses (filter changes, refrigerant checks, capacitor replacements, etc.). VoltAire heat exchangers have very low maintenance requirements due to no refrigerant or compressor.

Downtime Risk

Probability-weighted cost of equipment failure. Each option has a reliability multiplier based on historical MTBF data. Heat exchangers have the highest reliability (no compressor to fail).

FAQ

Frequently Asked Questions

How does this TCO calculator work?
The calculator combines four cost components over your selected time horizon (typically 10 years): (1) Capital cost — purchase price plus installation labor, including replacements when units reach end-of-life, (2) Electricity cost — average running watts × annual operating hours × your electricity rate, (3) Maintenance cost — typical annual service expenses, and (4) Expected downtime cost — probability-weighted risk based on each option's historical reliability. The result is the realistic 10-year cost of ownership for each option, not just the sticker price.
Where do the cost numbers come from?
VoltAire air-conditioner pricing is published list price drawn live from our catalog. VoltAire heat exchangers are quote-only, so their capital costs in this tool are illustrative estimates (marked with an asterisk) until you request current pricing. Competitor pricing for OEM enclosure ACs is NOT publicly listed (most competitors are quote-only through distributors), so the calculator uses customer-reported typical purchase prices for equivalent OEM units in the U.S. market — these are estimates, and actual quoted pricing varies by distributor, region, and quantity. Electricity consumption is based on nameplate ratings adjusted for typical duty cycles. Maintenance estimates and reliability factors are derived from industry-typical service data, not statistically validated benchmarks. Use this calculator as a planning framework, not a binding cost estimate. For an accurate side-by-side, request a quote from your competitor and a quote from VoltAire and run the numbers with real values.
Why do heat exchangers have lower TCO than air conditioners?
Three reasons: (1) lower purchase price, (2) dramatically lower electricity consumption — fans only, no compressor (typically 5-10x less power), and (3) longer service life with no compressor to wear out. The tradeoff is that heat exchangers can only cool to a few degrees above ambient, so they require ambient temperature lower than your target internal temperature to work.
What downtime cost should I use?
Downtime cost varies enormously by application. Use these typical ranges: small PLC cabinet ($500-2,000/hour), industrial process line ($5,000-25,000/hour), telecom site ($1,000-10,000/hour depending on subscribers affected), data center ($10,000-100,000/hour). If unsure, use $2,000/hour as a conservative default — it's a common figure for industrial enclosure failures.
How accurate is the "Do Nothing" option?
The "Do Nothing" baseline assumes no cooling investment but accounts for elevated equipment failure risk from running components above their rated temperatures. The 70% reliability assumption produces significant expected downtime cost. Real-world results vary widely — some operators run hot equipment for years without failure, while others see catastrophic component failure within months. Use this option as a conservative reference point.

Want a Custom TCO Analysis?

Tell us your specific operating conditions, heat load, and existing equipment. We'll run the numbers for your application and send a detailed proposal.